Tuesday, May 12, 2015

What is the best tilt for solar PV?

We have a 2 kW solar PV system, and solar hot water. Our house is a net exporter of electricity (we don't use gas). This is by quite a margin: our average consumption is about 3 kWh/day and our average export is about 6.5 kWh/day.

Thus, we export more than double the power that we import from the grid.

However, at this time of year our import/export is about equal. We are using slightly more power than during the shoulder season (though we're yet to boost our solar hot water), but the production of our solar PV system has markedly decreased. There are two reasons for this:
  1. The angle of the sun is much lower at this time of year, resulting in lower irradiance to the panels
  2. Cloud cover
Clearly, there's nothing that can be done about cloud cover. But it is the sun's angle I want to talk about here.

PV tilt

There has been much discussion of the optimal tilt for PV panels. Back when there was a well-paying feed-in-tariff (FiT), people advocated installing the panels nearly flat. At Southern Australian latitudes, the annual production of clean panels is maximised when they are flat (note the word clean -- below ~10 degrees tilt, panels must be manually cleaned).

Now that there is no FiT, the equation has changed. For me, the FiT is less of a consideration -- my goal is to to live within my solar budget throughout the year. But why?

EDIT: It is worth mentioning that choosing the "best" tilt is important for all solar collectors: solar thermal, solar hot water, and solar PV. If anything, it is more important for solar thermal than solar PV, since solar PV collects diffuse light energy from the sky and not just the sun.

Your solar budget

Growing up in an age of cheap fossil fuels, we have been conditioned to the idea that gratification follows expectation. Want to heat your house to 35 C in the middle of winter? Sure. Want an outside spa in the snow? sure. This simply will not happen in the age of renewables. For a society powered on solar and wind, there will be times (sustained cloudy and calm periods) where power is significantly more expensive. By "significant", I imagine 10 times dearer or more.

This can be mitigated by installing battery storage, however batteries are expensive. To install sufficient storage to provide during prolonged periods of low production will be out of reach for many. I think in Australia a 3 kWh (usable) battery system would (currently) be affordable by the majority, and might cost $3000 including installation. Note that such a system would really only provide power for one day, and then only for the frugal.

This is a side issue, about which I will elaborate in another post, let's get back to the PV tilt.

It's all about winter production

If you want to live within your means, it is the winter production that is crucial. There is a solar bounty in summer, so there's no problem there. Therefore, we need to increase the tilt of the panels to increase winter PV production. Here comes some maths:

Let's imagine we have a solar panel that is directly facing the sun. We would say that its surface is normal or perpendicular to the sun. This maximises the production because it catches as much sun as is possible.
Now, let's imagine that we tilt the panel so that it is not directly facing the sun. Now it catches less sunlight (its shadow is smaller) and so it will produce less energy. If we keep turning it, eventually it will cast no shadow (it's sideways to the sun) and receive no direct sunlight [1] and produce little.

So, as we turn the panel from directly facing the sun, to being side-on to the sun, let's imagine a scaling factor that describes the production of the panel. This factor will be decreasing as we increase the angle away form the sun form 0 degrees (facing) to 90 degrees (side on). The curve that describes this is called the cosine curve.
The cosine curve, showing how production decreases as the PV panel is tilted away from direct sunlight. Remember, that this does not consider energy production from diffuse light (in practice a panel will still produce energy if oriented away form the sun, it will just produce a lot less). Note that for low angles (less than, say, 20 degrees) there is little effect on production, but by 40 degrees it is falling sharply. That is the characteristic of the cosine function.

Looking at the amount of power exported from my house since September 2014, this pattern is clearly visible as we approach winter.
These data start on December 20 2014 (summer solstice) and the decrease in production through Autumn 2015 is clear.

My panels are oriented at about 23 degrees, which means that at the winter solstice, my panels are oriented about 40 degrees from ideal, significantly effecting production.

Given that we have lots of available PV power in summer, I would happily sacrifice a little to gain extra winter production and I would do this by increasing the tilt of my panels. I think the optimum would be to increase their tilt to about 45 degrees, which would reduce the winter sun's angle to about 20 degrees and increase winter production (at the cost of some summer production).

Conclusion

Orienting PV panels to ensure optimal winter production is a strategy that will help maximise your self-consumption. This helps you get the most from your PV system during all seasons.

-----------------
[1] PV panels also produce energy from diffuse light form the sky, but it is a lot less than direct sunlight. Here, we consider only the direct sunlight.

Monday, May 4, 2015

bits that fall through cracks

As I've described in how much do we use and renewable energy as investment, we have made an effort to reduce our power consumption, without going to absurd lengths. We regularly export about 8 kWh/day to the grid from our 2 kW solar PV system, and draw about 2 - 4 kWh/day from the grid. This is changing as we approach winter (read on).

As I said quite bluntly in Solar PV: opinions, merits, challenges, I am a believer in using the grid where it exists, because a battery storage system must be greatly oversized when off-grid to cope with the worst possible conditions -- conditions that are encountered only rarely [1]. Despite this, Australian utilities seem determined to cause grid defection: the process where people decide that they're economically better-off without the grid and leave it. I believe this will be a bad thing for Australia, because a lot of investment has already gone into the grid, and this will be wasted if people defect from it [2].

However, I'm also unhappy about our patterns of power use as they are. We don't have any fancy monitoring installed at our meter, I just take regular meter readings. I usually take a meter reading just before going to bed at about 10pm. Sometimes I check the meter again in the morning, just to see what has been used overnight. Without any intervention, we used about 1 kWh overnight.

Overnight power use

What's using all this power? Here's what I estimate/measure:
Consumption (W)
microwave0 (5)
mini oven0 (5)
fridge (continuous equiv)33
clock radio5
master bedroom cd player5
kids' bed cd5
computers-office10
macbook8
old laptop5
router10

Our Electrolux ETM4200SB fridge is one of the most efficient consumer fridges (we bought it second-hand for $500), and uses about 800 Wh daily, when the fridge's environment is about 24 C.  800 Wh/day is the same as 33 W (continuous equivalent) [3]. All the other values in the table are standby power consumption that I measured myself with a plug in Watt-meter. If you add all these values up, and multiply by 12 (hours), you get about 1 kWh used overnight. Note that I've counted the microwave and mini oven as having a standby power (also known as a phantom load) of zero -- that's because I switch off the microwave at the wall.

Clearly, if we want to draw less power from the grid, this is what needs to be reduced. Particularly at night when solar PV isn't producing. On windless nights, those electrons are supporting coal power, even though we buy GreenPower [4].

The fridge is the big one, and it would be good to get a fridge like the ozefridge, that can "store coldness" for use overnight (so that it doesn't use electricity at night time), but it's too expensive to justify right now -- if we were considering going off-grid it would be a no-brainer though (because storing energy in batteries is less efficient, with greater maintenance, than storing the energy as coldness in the fridge). 
I will install proper switches on the supply cables to the two CD players, and I want to put a timer on the office computers and router (so that they're properly off at night time). EDIT: I have found that the timers consume a significant amount of power and are unreliable, so I have just been switching things off or unplugging them.

Doing this reduces our overnight power consumption to about 0.5 kWh overnight (10pm to 7am).

Data:

(Note that the resolution of these measurements is 0.1 kWh, so they are a bit approximate)
  • I turned off the router and the two CD players overnight. Instead of using 1 kWh overnight, we used 0.7 kWh.
  • Then I turned off the study computers and washing machine too, which reduced our consumption to 0.6 kWh overnight (I bought cheap powerboards for the study PCs (~$10 each) that have a switch on them that turns off the whole board)
  •  If I turn off the router overnight our consumption is about 0.5 kWh overnight.
  • We've unfortunately needed to run a night-light for the kids, which is using almost 0.1 kWh overnight
In looking to save power, this is a significant saving for us (about 20% of our total grid draw), for very minimal effort and no sacrifice.

Solar -- Winter

This is a sun path diagram. It slows the path of the sun through the sky in Adelaide across the year. The upper green line (top of the yellow area) is the path taken at the Winter solstice. The lower blue line (bottom of the yellow area) is the path taken at the Summer solstice. The red line is the path taken on May 5th (today) -- you can see it is not far from the Winter solstice path, even though the Winter solstice is nearly two months away (this is because the path the sun takes is a sinusoidal curve, and the time of greatest rate-of-change is behind us (that occurs at the Autumn/Spring equinoxes) -- the rate of change occurring near the Solstices is small (for example, if you pay attention to the time of sunrise and sunset, you'll notice it changes most rapidly at the equinox, and most slowly at the solstice).
Sun path diagram. The original is here

Below are meter reading data that I have collected. In these data, look at the date and the pattern of solar PV production and electricity consumption is clearly variable as the seasons progress. In particular, the decrease in solar PV production (green line) during Winter is marked.
Also obvious is the large change in grid-draw (red line) that occurred on September 1st, 2014. That was when we switched off our electric storage hot water heater and went to solar hot water.
There is also a further reduction that occurs in early February 2015 -- this is the reduction that resulted from my targeting of phantom loads! It is subtle on this graph, but is clearer on the next graph which shows the cumulative data. The switch to solar hot water is also apparent in this graph, as an inflexion point at September 1st 2014, and a second inflexion point is visible at early February 2015. This shows that the savings from our reduction in phantom loads are significant.

Conclusion

Once the main areas of energy reduction are targeted,  it is very worthwhile to reduce phantom loads, particularly overnight. For essentially no effort, we're saving money every day, and reducing our support for coal and gas fired electricity.

------------
[1] Another alternative is that off-gridders accept that sometimes they run out of power, and use candles for light, fire for cooking, and nothing else. This is fairly widely accepted by rural off-gridders, but something tells me that city folk will be less inclined to accept this.
[2] Note the idea of a proposal being "economical" -- I don't believe that economics adequately captures many of the most important elements in a decision, and that this is due to economic externalities (economic costs being imposed on non-players). Let's take an example. It is widely considered that cheaper to install a larger solar PV system and use the excess electricity to heat water. It costs less money. This is because solar panels are artificially cheap (their cost to society is much higher than the price paid for them -- I won't substantiate this claim here, it's an article to itself, but there are many such articles written already). In comparison, the monetary cost to install a solar hot water system (that uses sunlight to heat water directly, without converting it to electricity) is higher but the cost to society much lower.
This shows that "economic considerations" are not necessarily indicative of overall merit.

[3] I have considered playing with the fridge's thermostat. My idea was to run the fridge much colder during the day, then raise the thermostat so it didn't work as hard at night time. This would make a dent in our night-time consumption. I haven't done anything with this idea yet (there are clearly food-hygiene considerations here!)

[4] This is probably a somewhat contreversial statement. We buy 100% Greenpower, so in theory our power is all sourced from renewables. However, if there is a windless night, then any power consumption increases the electricity spot price, which aids coal/gas fired power stations (currently there is almost no storage of renewable energy in the grid).


This article was written by Angus Wallace, and first appeared at guesstimatedapproximations.blogspot.com.au

Tuesday, April 28, 2015

Kitchen hot water

A while ago, I wrote about my reasons for wanting a dedicated hot water system for the kitchen. Today, the system is finally operational. It's a big day!

I decided I wanted to do all the plumbing myself, which has made things take a bit longer (I have no previous experience brazing or bending copper pipe), but it has gone reasonably smoothly (albeit slowly), and in the end I'm reasonably happy with the standard of work. I left the most visible parts until last, when I'd had most practice and they look reasonably professional.

Here is a picture of the little hot water system on the roof (with the unfinished space heater next to it). It holds 30L of water, and has 8 x 50cm evacuated tubes. It is a low pressure system, so I can't just connect it to mains pressure with a tap in the kitchen (as is the norm). This system cost me $300 on ebay. It came with the aluminium racking immediately underneath it, but all the rest of the aluminium on the roof I installed myself.

Because the unit can't run at mains pressure, I needed a system whereby the tap to it controls its supply (before that supply reaches the tank). Then the tank is just sitting there at atmospheric pressure. To do this, I used an electric solenoid valve, which cost about $20 on ebay, with a 12 V transformer that I installed in the roof. We had an existing powerpoint in the roof that is controlled by a switch in the kitchen. That switch now energises the solonoid valve, switching it from normally-closed to open and allowing more water to flow into the tank of the hot water system.
Because the tank is always basically full, this causes it to overflow. The overflowing water exits the tank via the (hard-to-see) pipe at the top-left in the first image, and that pipe leads straight down to a (tapless) faucet in the kitchen below. Here is the last bit of pipework that directs that overflow through the kitchen window and out the spout in the kitchen.

How to use it

In the kitchen, flick the power switch, and wait. That switch activates the solonoid valve, opening it. Water enters the tank and causes it to overflow, and come out of the kitchen faucet (separate to the existing tapware). A bit before we have enough water, flick the switch back off -- the rest of the water will drain from the pipe into the sink before it stops.

 Quirks

Yes, this is quite an unusual system.

The main quirk is that, because the "overflow" pipe is basically empty of water most of the time, there is quite a latency between flicking the switch and getting water out of the tap. There is also quite a latency between un-flicking the switch and the water stopping. There's more testing to go here, but I think it's about 20 seconds.

Also, because the faucet is open to the tank, it is possible that the tank will boil in summer and lead to dripping in the kitchen. This remains to be seen.

Reflection on goals


The goal was to have "instant solar hot water" available at the flick of a switch. I now think this was a bit naive, but I still think it will be handy for two main reasons:
  1. Because it is a shorter run of hot water (it is basically hot immediately with no wastage), it decreases the load on the main solar HWS during winter. 
  2.  For the same reason, less water is wasted in summer (when we really need it!) -- we've been catching that water in jugs and drinking it later, but it is a bit of a pain, and still results in some wastage (from the main HWS, there is just over 2 L wastage to get hot water in the kitchen)
If I was doing this again, I'd consider installing an additional full-size solar HWS down that end of the house and just run the kitchen from that. One day, I may do that (depending how we go for hot water in winter).

Monday, April 20, 2015

Update on water systems (part II)

I wrote progress report on our water systems at the beginning of January. This weekend, we had the first solid rain since then. That is over 70 days without significant rain. This weekend, I estimate we caught about 8 kL in our tanks, so the summer dry spell is officially over.

From reading the water meter, we used 8.5 kL from town water over summer to make up the shortfall in stored rainwater. I estimate that
  1. I accidentally released 3 - 4 kL from the tanks into the garden in late January
  2. The tanks at the front of the house were only connected in December, which meant we only collected 1/2 of the spring rains
Were the summer to be repeated, I think our water would last. But, can we expect future summers to be similar to the 2014/2015 summer?

This summer, versus historical summers

This summer was not unusually dry -- if anything, the rain that we had at the beginning of January was unusual and is unlikely to be repeated every year. Here's what the data say for Adelaide:


All numbers are mm of rainfall for that month. the statistics [1] were calculated over all the historical rain data I have for Adelaide (since 1884). For the purpose of this analysis I've assumed the data are stationary (ie. there's been no change in Adelaide's rainfall patterns in that time).

Assuming the rainfall distribution is normal (a wrong assumption, but probably doesn't matter for this), 35% of years will be within 1 standard deviation of the mean. Note that for the months November to March this means that 1/3 of those months can be expected to have basically no rain at all! (Note that I haven't looked at inter-dependencies in the data (ie. Does a dry February tend to follow a dry January (which it probably does)?)

For the summer just gone,  here are the numbers



Every month except January was drier than average, but none by much more than one standard deviation. In other words, it was a dry summer but it was not unusually dry.

Rainwater Model

Based on this summer's data, I've revised my rainwater model a bit. Mainly I've realised that although I have 37 kL storage, I probably only have 30 kL of usable storage. I've also increased the washing machine frequency to daily, from 0.8 times per day. Looking at the historical data, we would now have run out five years since 1884.

Lessons

I set up a dripper system on the garden, and believe I wasted a lot of water there. Next summer, I want to move to wicking beds for the annual crops.
I also want to have a functioning composting toilet, which will save more water.


[1] Standard deviation is a measure of how variable the data are. In this case, it is a measure of how likely it is that a given year is a long way from the mean (average) rainfall. For normally distributed data, about 1/3 of years will be within one standard deviation of the mean, and about 7% being more than 3 standard deviations away from it. More info on wikipedia.


-----------
This article was written by Angus Wallace, and first appeared at guesstimatedapproximations.blogspot.com.au


Creative Commons License
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.